Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Clin Sci (Lond) ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38718356

RESUMEN

The three striatins (STRN, STRN3, STRN4) form the core of STRiatin-Interacting Phosphatase and Kinase (STRIPAK) complexes.  These place protein phosphatase 2A (PP2A) in proximity to protein kinases thereby restraining kinase activity and regulating key cellular processes.  Our aim was to establish if striatins play a significant role in cardiac remodelling associated with cardiac hypertrophy and heart failure.  All striatins were expressed in control human hearts, with upregulation of STRN and STRN3 in failing hearts.  We used mice with global heterozygote gene deletion to assess the roles of STRN and STRN3 in cardiac remodelling induced by angiotensin II (AngII; 7 days).  Using echocardiography, we detected no differences in baseline cardiac function or dimensions in STRN+/- or STRN3+/- male mice (8 weeks) compared with wild-type littermates.  Heterozygous gene deletion did not affect cardiac function in mice treated with AngII, but the increase in left ventricle mass induced by AngII was inhibited in STRN+/- (but not STRN3+/-) mice. Histological staining indicated that cardiomyocyte hypertrophy was inhibited.  To assess the role of STRN in cardiomyocytes, we converted the STRN knockout line for inducible cardiomyocyte-specific gene deletion.  There was no effect of cardiomyocyte STRN knockout on cardiac function or dimensions, but the increase in left ventricle mass induced by AngII was inhibited.  This resulted from inhibition of cardiomyocyte hypertrophy and cardiac fibrosis.  The data indicate that cardiomyocyte striatin is required for early remodelling of the heart by AngII and identify the striatin-based STRIPAK system as a signalling paradigm in the development of pathological cardiac hypertrophy.

2.
J Clin Med ; 13(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38276098

RESUMEN

Transcatheter aortic valve implantation (TAVI) is now well established as the treatment of choice for patients with native aortic valve stenosis who are high or intermediate risk for surgical aortic valve replacement. Recent data has also supported the use of TAVI in patients at low surgical risk and also in anatomical subsets that were previously felt to be contra-indicated including bicuspid aortic valves and aortic regurgitation. With advancements and refinements in procedural techniques, the application of this technology has now been further expanded to include the management of degenerated bioprosthesis. After the demonstration of feasibility and safety in the management of degenerated aortic bioprosthetic valves, mitral and tricuspid bioprosthetic valve treatment is now also well-established and provides an attractive alternative to performing redo surgery. In this review, we appraise the latest clinical evidence and highlight procedural considerations when utilising TAVI technology in the management of degenerated aortic, mitral or tricuspid prosthesis.

3.
J Atheroscler Thromb ; 31(3): 316-325, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37743505

RESUMEN

AIM: This study aimed to investigate whether skin autofluorescence (SAF) is associated with clinical outcomes in patients with coronary artery disease. Advanced glycation end products (AGE) play a crucial role in atherosclerosis. Accumulation of AGE can be measured non-invasively by SAF. METHODS: We performed a single-center prospective study of 896 patients with coronary artery disease treated with percutaneous coronary intervention (PCI) between January 2014 and December 2015. SAF was measured before the PCI procedure. The primary endpoint was patient-oriented composite endpoints (POCE) defined as a composite of all-cause death, any myocardial infarction, any stroke, and any revascularization. RESULTS: Patients were significantly older and suffered higher rates of chronic kidney disease (CKD) in the high SAF group. A higher SAF was associated with an increased risk for POCE (HR 1.43; 95% CI 1.19-1.71, p<0.001) that was mainly driven by any coronary revascularization (HR 1.33; 95% CI 1.08-1.65, p=0.01) including target lesion revascularization (HR 1.41; 95% CI 1.02-1.94, p=0.04). The higher SAF group also experienced worse outcomes in stroke (HR 2.08; 95% CI 1.38-3.15, p=0.001). Multivariate analyses indicated that SAF was an independent predictor of POCE (HR 1.36; 95% CI 1.13-1.63, p=0.001). CONCLUSIONS: SAF as a measure of AGE deposition is independently associated with cardiovascular events amongst patients with coronary artery disease treated with PCI. SAF also predicts the incidence of restenosis and stroke.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Humanos , Enfermedad de la Arteria Coronaria/etiología , Estudios Prospectivos , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Piel , Productos Finales de Glicación Avanzada , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
4.
N Engl J Med ; 389(25): 2319-2330, 2023 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-38015442

RESUMEN

BACKGROUND: Percutaneous coronary intervention (PCI) is frequently performed to reduce the symptoms of stable angina. Whether PCI relieves angina more than a placebo procedure in patients who are not receiving antianginal medication remains unknown. METHODS: We conducted a double-blind, randomized, placebo-controlled trial of PCI in patients with stable angina. Patients stopped all antianginal medications and underwent a 2-week symptom assessment phase before randomization. Patients were then randomly assigned in a 1:1 ratio to undergo PCI or a placebo procedure and were followed for 12 weeks. The primary end point was the angina symptom score, which was calculated daily on the basis of the number of angina episodes that occurred on a given day, the number of antianginal medications prescribed on that day, and clinical events, including the occurrence of unblinding owing to unacceptable angina or acute coronary syndrome or death. Scores range from 0 to 79, with higher scores indicating worse health status with respect to angina. RESULTS: A total of 301 patients underwent randomization: 151 to the PCI group and 150 to the placebo group. The mean (±SD) age was 64±9 years, and 79% were men. Ischemia was present in one cardiac territory in 242 patients (80%), in two territories in 52 patients (17%), and in three territories in 7 patients (2%). In the target vessels, the median fractional flow reserve was 0.63 (interquartile range, 0.49 to 0.75), and the median instantaneous wave-free ratio was 0.78 (interquartile range, 0.55 to 0.87). At the 12-week follow-up, the mean angina symptom score was 2.9 in the PCI group and 5.6 in the placebo group (odds ratio, 2.21; 95% confidence interval, 1.41 to 3.47; P<0.001). One patient in the placebo group had unacceptable angina leading to unblinding. Acute coronary syndromes occurred in 4 patients in the PCI group and in 6 patients in the placebo group. CONCLUSIONS: Among patients with stable angina who were receiving little or no antianginal medication and had objective evidence of ischemia, PCI resulted in a lower angina symptom score than a placebo procedure, indicating a better health status with respect to angina. (Funded by the National Institute for Health and Care Research Imperial Biomedical Research Centre and others; ORBITA-2 ClinicalTrials.gov number, NCT03742050.).


Asunto(s)
Angina Estable , Intervención Coronaria Percutánea , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome Coronario Agudo , Angina Estable/tratamiento farmacológico , Angina Estable/cirugía , Fármacos Cardiovasculares/uso terapéutico , Reserva del Flujo Fraccional Miocárdico , Estado de Salud , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento , Método Doble Ciego , Isquemia Miocárdica
5.
J Clin Med ; 12(14)2023 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-37510783

RESUMEN

The past decade has seen a marked expansion in the understanding of the pathobiology of acute myocardial infarction and the systemic inflammatory response that it elicits. At the same time, a portfolio of tools has emerged to characterise some of these processes in vivo. However, in clinical practice, key decision making still largely relies on assessment built around the timing of the onset of chest pain, features on electrocardiograms and measurements of plasma troponin. Better understanding the heterogeneity of myocardial injury and patient-level responses should provide new opportunities for diagnostic stratification to enable the delivery of more rational therapies. Characterisation of the myocardium using emerging imaging techniques such as the T1, T2 and T2* mapping techniques can provide enhanced assessments of myocardial statuses. Physiological measures, which include microcirculatory resistance and coronary flow reserve, have been shown to predict outcomes in AMI and can be used to inform treatment selection. Functionally informative blood biomarkers, including cellular transcriptomics; microRNAs; extracellular vesicle analyses and soluble markers, all give insights into the nature and timing of the innate immune response and its regulation in acute MI. The integration of these and other emerging tools will be key to developing a fuller understanding of the patient-level processes of myocardial injury and repair and should fuel new possibilities for rational therapeutic intervention.

6.
J Thromb Haemost ; 21(8): 2213-2222, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37230416

RESUMEN

BACKGROUND: Patients hospitalized with COVID-19 suffer thrombotic complications. Risk factors for poor outcomes are shared with coronary artery disease. OBJECTIVES: To investigate the efficacy of an acute coronary syndrome regimen in patients hospitalized with COVID-19 and coronary disease risk factors. METHODS: A randomized controlled, open-label trial across acute hospitals (United Kingdom and Brazil) added aspirin, clopidogrel, low-dose rivaroxaban, atorvastatin, and omeprazole to standard care for 28 days. Primary efficacy and safety outcomes were 30-day mortality and bleeding. The key secondary outcome was a daily clinical status (at home, in hospital, on intensive therapy unit admission, or death). RESULTS: Three hundred twenty patients from 9 centers were randomized. The trial terminated early due to low recruitment. At 30 days, there was no significant difference in mortality (intervention vs control, 11.5% vs 15%; unadjusted odds ratio [OR], 0.73; 95% CI, 0.38-1.41; p = .355). Significant bleeds were infrequent and were not significantly different between the arms (intervention vs control, 1.9% vs 1.9%; p > .999). Using a Bayesian Markov longitudinal ordinal model, it was 93% probable that intervention arm participants were more likely to transition to a better clinical state each day (OR, 1.46; 95% credible interval [CrI], 0.88-2.37; Pr [beta > 0], 93%; adjusted OR, 1.50; 95% CrI, 0.91-2.45; Pr [beta > 0], 95%) and median time to discharge to home was 2 days shorter (95% CrI, -4 to 0; 2% probability that it was worse). CONCLUSION: Acute coronary syndrome treatment regimen was associated with a reduction in the length of hospital stay without an excess in major bleeding. A larger trial is needed to evaluate mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19 , Humanos , SARS-CoV-2 , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/tratamiento farmacológico , Teorema de Bayes , Aspirina/uso terapéutico , Hemorragia/inducido químicamente , Hemorragia/tratamiento farmacológico , Resultado del Tratamiento
7.
J Thromb Haemost ; 21(8): 2248-2259, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37085037

RESUMEN

BACKGROUND: The response of platelets to activating stimuli and pharmaceutical agents varies greatly within the normal population. Current platelet function tests are used to measure end-point levels of platelet activation without taking the speed at which platelets activate into account, potentially missing vital metrics to characterize platelet reactivity. OBJECTIVES: To identify variability, to agonists and among individuals, in platelet activation kinetics and assess the impact of this on thrombus formation. METHODS: We have developed a bespoke real-time flow cytometry assay and analysis package to measure the rate of platelet activation over time using 2 parameters of platelet activation, fibrinogen binding and P-selectin exposure. RESULTS: The rate of platelet activation varied considerably within the normal population but did not correlate with maximal platelet activation, demonstrating that platelet activation rate is a separate and novel metric to describe platelet reactivity. The relative rate of platelet response between agonists was strongly correlated, suggesting that a central control mechanism regulates the rate of platelet response to all agonists. CONCLUSION: For the first time, we have shown that platelet response rate corresponds to thrombus size and structure, wherein faster responders form larger, more densely packed thrombi at arterial, but crucially not venous, shear. We have demonstrated that the rate of platelet activation is an important metric in stratifying individual platelet responses and will provide a novel focus for the design and development of antiplatelet therapy, targeting high-shear thrombosis without exacerbating bleeding at low shear.


Asunto(s)
Activación Plaquetaria , Trombosis , Humanos , Trombosis/metabolismo , Plaquetas/metabolismo , Pruebas de Función Plaquetaria , Arterias , Agregación Plaquetaria
8.
J. thromb. haemost ; 21: 2213-2222, Apr. 2023. graf, ilus, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1435649

RESUMEN

BACKGROUND: patients hospitalised with covid-19 suffer thrombotic complications. risk factors for poor outcomes are shared with coronary artery disease. Objectives: to investigate efficacy of an acute coronary syndrome regimen in patients hospitalised with covid-19 and coronary disease risk factors. PATIENTS/METHODS: a randomised controlled open-label trial across acute hospitals (uk and brazil) added aspirin, clopidogrel, low-dose rivaroxaban, atorvastatin, and omeprazole to standard care for 28-days. primary efficacy and safety outcomes were 30-day mortality and bleeding. the key secondary outcome was a daily clinical status (at home, in hospital, on intensive therapy unit admission, death). RESULTS: 320 patients from 9 centres were randomised. the trial terminated early due to low recruitment. at 30 days there was no significant difference in mortality (intervention: 11.5% vs control: 15%, unadjusted or 0.73, 95%ci 0.38 to 1.41, p=0.355). significant bleeds were infrequent and not significantly different between the arms (intervention: 1.9% vs control 1.9%, p>0.999). using a bayesian markov longitudinal ordinal model, it was 93% probable that intervention arm participants were more likely to transition to a better clinical state each day (or 1.46, 95% cri 0.88 to 95 2.37, pr(beta>0) =93%; adjusted or 1.50, 95% cri 0.91 to 2.45, pr(beta>0) =95%) and median time to discharge home was two days shorter (95% cri -4 to 0, 2% probability that it was worse). CONCLUSIONS: acute coronary syndrome treatment regimen was associated with a 99 reduction in the length of hospital stay without an excess in major bleeding. a larger trial is needed to evaluate mortality.


Asunto(s)
Síndrome Coronario Agudo , COVID-19
9.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100349, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35992189

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) is the treatment of choice for patients with severe aortic stenosis who are at a moderate or higher surgical risk. Stroke is a recognised and serious complication of TAVR, and it is important to identify patients at higher stroke risk. This study aims to discover if aortic valve calcium score calculated from pre-TAVR computed tomography is associated with acute stroke in TAVR patients. Methods: We conducted a retrospective, observational cohort study of 433 consecutive patients undergoing TAVR between January 2017 and December 2019 at the Hammersmith Hospital. Results: This cohort had a median age of 83 years (interquartile range, 78-87), and 52.7% were male. Fifty-two patients (12.0%) had a history of previous stroke or transient ischemic attack. Median aortic valve calcium score was 2145 (interquartile range, 1427-3247) Agatston units. Twenty-two patients had a stroke up to the time of discharge (5.1%). In a logistic regression model, aortic valve calcium score was significantly associated with acute stroke (odds ratio [OR], 1.26; 95% confidence interval [CI], 1.01-1.53; P = .02). Acute stroke was also significantly associated with peripheral arterial disease (OR, 4.32; 95% CI, 1.65-10.65; P = .0018) and a longer procedure time (OR, 1.01; 95% CI, 1.00-1.02; P = .0006). Conclusions: Aortic valve calcium score from pre-TAVR computed tomography is an independent risk factor for acute stroke in the TAVR population. This is an additional clinical value of the pre-TAVR aortic valve calcium score and should be considered when discussing periprocedural stroke risk.

10.
JACC Case Rep ; 4(13): 794-798, 2022 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-35818596

RESUMEN

Transfemoral transcatheter aortic valve replacement is an effective treatment for severe aortic stenosis with a high rate of procedural success with the current devices. However, anatomic factors and device limitations may increase technical difficulty. We describe the balloon nudge technique, a novel technique that improves coaxial alignment while crossing the aortic valve. (Level of Difficulty: Advanced.).

11.
Cardiovasc Revasc Med ; 36: 153-163, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34366296

RESUMEN

Percutaneous closure of paravalvar leaks (PVLs) was once only performed in extreme or non-surgical risk cases not suitable for redo-surgery with tissue or mechanical valves. This technique is now the treatment of choice with long term outcomes that are better than redo operations.123 As interventionalists become more familiar with using PVL devices, more off label device use has been reported in non-surgical cases involving complex native mitral valve regurgitation (NVMR). In this review, we appraise the literature regarding percutaneous treatment of paravalvar leaks and more recently esoteric off label use. We also describe two recent challenging cases where percutaneous devices were used to treat severe leaks that developed as a sequela of previous infective endocarditis. We also provide specific recommendations regarding periprocedural strategy and focus on the importance of device choice to provide an optimal outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Catéteres , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
13.
Open Heart ; 8(1)2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33723014

RESUMEN

OBJECTIVES: The clinical impact of SARS-CoV-2 has varied across countries with varying cardiovascular manifestations. We review the cardiac presentations, in-hospital outcomes and development of cardiovascular complications in the initial cohort of SARS-CoV-2 positive patients at Imperial College Healthcare National Health Service Trust, UK. METHODS: We retrospectively analysed 498 COVID-19 positive adult admissions to our institute from 7 March to 7 April 2020. Patient data were collected for baseline demographics, comorbidities and in-hospital outcomes, especially relating to cardiovascular intervention. RESULTS: Mean age was 67.4±16.1 years and 62.2% (n=310) were male. 64.1% (n=319) of our cohort had underlying cardiovascular disease (CVD) with 53.4% (n=266) having hypertension. 43.2%(n=215) developed acute myocardial injury. Mortality was significantly increased in those patients with myocardial injury (47.4% vs 18.4%, p<0.001). Only four COVID-19 patients had invasive coronary angiography, two underwent percutaneous coronary intervention and one required a permanent pacemaker implantation. 7.0% (n=35) of patients had an inpatient echocardiogram. Acute myocardial injury (OR 2.39, 95% CI 1.31 to 4.40, p=0.005) and history of hypertension (OR 1.88, 95% CI 1.01 to 3.55, p=0.049) approximately doubled the odds of in-hospital mortality in patients admitted with COVID-19 after other variables had been controlled for. CONCLUSION: Hypertension, pre-existing CVD and acute myocardial injury were associated with increased in-hospital mortality in our cohort of COVID-19 patients. However, only a low number of patients required invasive cardiac intervention.


Asunto(s)
COVID-19/epidemiología , Enfermedades Cardiovasculares/epidemiología , Pandemias , Anciano , Comorbilidad , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Incidencia , Londres , Masculino , ARN Viral/análisis , Estudios Retrospectivos , SARS-CoV-2/genética , Tasa de Supervivencia/tendencias
14.
Perfusion ; 36(6): 547-558, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33427055

RESUMEN

The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.


Asunto(s)
COVID-19 , Cardiología , Ecocardiografía , Humanos , Pandemias , SARS-CoV-2
15.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32865860

RESUMEN

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Complicaciones Posoperatorias , Prevalencia , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
Ther Adv Cardiovasc Dis ; 14: 1753944720977732, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33274695

RESUMEN

AIMS: To determine whether the number of patients presenting with acute coronary syndromes has reduced during the COVID-19 pandemic. METHODS: Numbers of primary percutaneous coronary intervention (PPCI) activations, ST elevation myocardial infarctions (STEMIs) and non-ST elevation myocardial infarctions (NSTEMIs) in a large tertiary Greater London centre and a large district general hospital, both of which have on-site heart attack centres, were collected. We compared the number of PPCI activations, STEMI, NSTEMIs and all MIs prior to the COVID-19 era (January to third week of February 2020), after the start of some COVID-19 restrictions taking place (fourth week of February 2020) and after formal instruction by the United Kingdom Government that all citizens were to observe strict social distancing measures (20 March 2020). We further obtained data for the corresponding weekly figures from 2019. RESULTS: The average weekly figure of all myocardial infarction in 2020, prior to the COVID-19 social distancing restrictions/awareness in the UK (beginning of January to third week of February), did not differ when compared with corresponding weeks in 2019 (23.3 ± 5.4 in 2019 versus 21.13 ± 3.5, p = 0.411).With increased media reporting and associated public awareness of the threat of COVID-19 (last week of February), there was a significant reduction in all myocardial infarction (27.1 ± 4.7 in 2019 versus 15.9 ± 3.6 in 2020, p < 0.001). Following official governmental instruction that mandated strict social distancing and the 'stay at home' campaign, the weekly figures of STEMI (15 ± 3.5 in 2019 versus 10 ± 4.4 in 2020, p = 0.013), NSTEMI (13 ± 2.6 in 2019 versus 4.7 ± 2.3 in 2020, p = 0.038) and all myocardial infarction (28 ± 6.1 in 2019 versus 14.7 ± 5.7 in 2020, p = 0.008) have remained significantly reduced. CONCLUSION: We have observed an unexpected major decline in presentations (and treatment) of the entire spectrum of acute coronary syndromes following the beginning of the COVID-19 pandemic and nationwide public-health measures that have promoted the importance of strict social distancing and self-quarantine.


Asunto(s)
Síndrome Coronario Agudo/epidemiología , COVID-19/epidemiología , Infarto del Miocardio sin Elevación del ST/epidemiología , Infarto del Miocardio con Elevación del ST/epidemiología , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Anciano , Anciano de 80 o más Años , COVID-19/diagnóstico , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Humanos , Londres/epidemiología , Masculino , Infarto del Miocardio sin Elevación del ST/diagnóstico , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/tendencias , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Factores de Tiempo
17.
Cardiovasc Revasc Med ; 21(11S): 11-13, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32747197

RESUMEN

Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for severe symptomatic aortic stenosis (Leon et al., 2016), and recently has also been utilised for bioprosthetic surgical aortic valve (sAVR) failure (valve-in-valve TAVR (ViV-TAVR)) (Yoon et al., 2017; Nalluri et al., 2018). Data supporting ViV-TAVR are limited to observational studies but suggest similar outcomes to re-do sAVR in high risk patients (Barbanti et al., n.d.). Whilst bioprosthetic SAVR failure is well documented, TAVR failure is less well described (Barbanti et al., n.d.). Here, we describe a case of TAVR failure in a previous sAVR resulting in the need for emergent valve-in-valve-in-valve TAVR (ViViV-TAVR).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Factores de Riesgo , Resultado del Tratamiento
19.
Clin Med (Lond) ; 20(2): 174-177, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32188654

RESUMEN

The incidence of acute ischaemic stroke in young patients is increasing and identifying the underlying cause is critically important with regards to their optimal management. The true proportion of cardiac causes of stroke in young patients is poorly defined. We aimed to determine the proportion of strokes attributable to cardiac causes in an unselected, consecutive cohort of young patients. We used the database of a large stroke service to identify patients aged ≤55 years presenting with stroke between 01 January 2015 and 31 December 2017. We reviewed their clinical notes and investigations and then categorised patients by the cause of their stroke.We screened 202 cases, and excluded 35, resulting in a study population of 167 patients; 24.0% (40/167) had a cardiac cause of stroke including 9.6% (16/167) had patent foramen ovale, 9.0% (15/167) had intracardiac source of embolus and 5.4% (9/167) had atrial fibrillation; 50.8% (85/167) had other more likely causes; and 25.1% (42/167) had no clear underlying cause.A high proportion (24%) of strokes in young patients are secondary to a cardiac cause. Thorough investigation in these patients is warranted and requires close interdisciplinary links between cardiologists and stroke physicians to ensure optimal management.


Asunto(s)
Fibrilación Atrial , Isquemia Encefálica , Foramen Oval Permeable , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Isquemia Encefálica/epidemiología , Isquemia Encefálica/etiología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/epidemiología , Humanos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
20.
Int J Cardiol ; 310: 120-125, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32139239

RESUMEN

BACKGROUND: The Evolut PRO self-expanding transcatheter aortic valve has been designed to feature an outer pericardial wrap that aims to reduce paravalvular regurgitation (PVR) rates. Medium-term clinical outcomes, compared to its predecessor Evolut R, in a real-world setting, have not been investigated. The aim of the present study was to compare the two valves with regards to peri-procedural complications, early outcomes and mid-term survival. METHODS: Consecutive patients, undergoing TAVI with either the Evolut PRO or Evolut R device, from the multicenter ATLAS registry were retrospectively studied. Outcomes studied included periprocedural complications, PVR at discharge, need for new pacemaker implantation and Kaplan-Meier estimated 1-year all-cause mortality. RESULTS: Analysis included 673 patients (498 treated with Evolut R and 175 treated with Evolut PRO). At least moderate PVR was numerically lower amongst patients treated with Evolut PRO (7.4% vs 3.8% for Evolut R and Evolut PRO respectively, p = .108). Rates of new permanent pacemaker (PPM) implantation (21.1% vs. 11.9%, p = .023), and bail-out valve-in-valve (2.4% vs. 0%, p = .049) were significantly lower amongst the Evolut PRO group. No differences were demonstrated regarding bleeding, stroke or acute kidney injury. One-year Kaplan-Meier estimated survival was similar between groups (93% for Evolut R vs. 91.2% for Evolut PRO, plog-rank = 0.806). CONCLUSIONS: The Evolut PRO self-expanding valve demonstrates similar mid-term survival rates and numerically, yet not significant, lower incidence of PVR compared to its predecessor. Interestingly this new generation valve is associated with a significantly reduced rate for new PPM implantation. Future studies are required to confirm this finding.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...